Core Count : 2P, 3P, 4P, 5P, 6P, 7P, 8P
Category : Female
Installation Method : Screw type
Direction : 90°
Applications : Power, Signal
Full metal screw type elbow:Shell design: Made of zinc alloy plated with nickel, it has high mechanical strength and is corrosion-resistant; 90° radial outlet design, suitable for narrow spaces such as mechanical arm joints. Reliable and convenient connection: No professional skills are required for screw wiring, the anti-slip teeth pattern combined with the threaded locking structure reduces cable slippage and loosening under high-frequency vibration, and has high contact stability. High environmental tolerance: The full metal shell is impact-resistant and pressure-resistant, with high protection level and wide temperature design, capable of working stably in harsh environments such as oil stains, humidity, and dust. Application scenarios: Suitable for industrial robot joints, AGV carts, machine tool encoders, ship machinery, mining equipment, and compact outdoor sensors.
|
Product model
|
Core
|
Rated current
|
Rated voltage
|
Wire gauge / Dimension
|
||
|
A/C
|
D/C
|
AWG
|
mm²
|
|||
| MC12AF-02U4LJZSR102 |
2
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12AF-03U4LJZSR102 |
3
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12AF-04U4LJZSR102 |
4
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12AF-05U4LJZSR102 |
5
|
4A
|
60V
|
60V
|
22
|
0.34
|
| MC12AF-06U4LJZSR102 |
6
|
2A
|
30V
|
30V
|
24
|
0.25
|
| MC12AF-08U4LJZSR102 |
8
|
2A
|
30V
|
30V
|
24
|
0.25
|
| Core | 2A | 3A | 4A | 5A |
| male end |
|
|
|
|
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
||
| Core | 2A | 3A | 4A | 5A |
| female connector |
|
|
|
|
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
|
The connector must not be plugged or unplugged under load. Failure to follow the instructions and improper use can result in personal injury.
The development of the connector is aimed at being applied in factory engineering, control and electrical equipment construction. Users are responsible for checking whether the connector can also be used in other applications.
Connectors used in circuits with dangerous voltages that cause electric shock must be installed and used only by personnel who have received training in electrical engineering, or under their supervision, while taking into account the applicable regulations and standards.
Users must take appropriate security measures to ensure that the connectors do not accidentally disconnect.
When installing, apply moderate force and use the special tool to tighten the nuts. Avoid excessive force to prevent the shell from deforming or the pins from bending. Ensure that the plug and socket are fully engaged. Do not power on the device when not locked in place to prevent arc discharge due to poor contact.
The plug connectors with an enclosure protection rating of IP67 and IP68 are not suitable for use in water. When used outdoors, the plug connectors must be protected against corrosion separately. For further information on IP protection ratings, please refer to "Technical Information".