Core Count : 2P, 3P, 4P, 5P, 6P, 7P, 8P, 12P, 17P
Category : Female
Installation Method : Welding wire type
Direction : 110°
Applications : Power, Signal
Straight-through all-metal welded type:
All-metal housing: Usually made of zinc alloy plated with nickel, this housing has high strength and good corrosion resistance, effectively protecting the internal contacts while providing excellent electromagnetic shielding performance to prevent signal interference. Straight shape: Adopting a 180° direct-out design, the cables can naturally extend, reducing signal attenuation and the risk of cable damage, suitable for scenarios with spacious space and where straight-line connection of cables is required. Welded connection: Connecting the wires to the contact parts of the connector through welding, ensuring the stability and reliability of the connection, reducing contact resistance, and guaranteeing stable transmission of signals and current. Application scenarios: Widely used in industrial automation, rail transportation, and mechanical equipment.
|
Product model
|
Core
|
Rated current
|
Rated voltage
|
Wire gauge / Dimension
|
||
|
A/C
|
D/C
|
AWG
|
mm²
|
|||
| MC12AF-02U2LSLSR101 |
2
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12AF-03U2LSLSR101 |
3
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12AF-04U2LSLSR101 |
4
|
4A
|
250V
|
250V
|
22
|
0.34
|
| MC12AF-05U2LSLSR101 |
5
|
4A
|
60V
|
60V
|
22
|
0.34
|
| MC12AF-06U2LSLSR101 |
6
|
2A
|
30V
|
30V
|
24
|
0.25
|
| MC12AF-08U2LSLSR101 |
8
|
2A
|
30V
|
30V
|
24
|
0.25
|
| MC12AF-12U2LSLSR101 |
12
|
1.5A
|
30V
|
30V
|
26
|
0.14
|
| MC12AF-17U2LSLSR101 |
17
|
1.5A
|
30V
|
30V
|
26
|
0.14
|
| Core | 2A | 3A | 4A | 5A |
| male end |
|
|
|
|
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
||
| Core | 2A | 3A | 4A | 5A |
| female connector |
|
|
|
|
| 6A | 8A | 12A | 17A | |
|
|
|
|
|
|
| 4B | 5B | 3C | 4C | |
|
|
|
|
|
|
| 5C | 6C | 4D | ||
|
|
|
|
|
The connector must not be plugged or unplugged under load. Failure to follow the instructions and improper use can result in personal injury.
The development of the connector is aimed at being applied in factory engineering, control and electrical equipment construction. Users are responsible for checking whether the connector can also be used in other applications.
Connectors used in circuits with dangerous voltages that cause electric shock must be installed and used only by personnel who have received training in electrical engineering, or under their supervision, while taking into account the applicable regulations and standards.
Users must take appropriate security measures to ensure that the connectors do not accidentally disconnect.
When installing, apply moderate force and use the special tool to tighten the nuts. Avoid excessive force to prevent the shell from deforming or the pins from bending. Ensure that the plug and socket are fully engaged. Do not power on the device when not locked in place to prevent arc discharge due to poor contact.
The plug connectors with an enclosure protection rating of IP67 and IP68 are not suitable for use in water. When used outdoors, the plug connectors must be protected against corrosion separately. For further information on IP protection ratings, please refer to "Technical Information".