Available Pin Count : 4P
Type : Male
Mounting Method : Solder Type
Applications : Power, Signal
Rear Panel Mount, Solder Type:Mounting and Wiring Design:Adopting a rear panel mounting method, it is secured from the back of the panel with M8×1 threads and matching nuts, without occupying the front operating space of the equipment. It is suitable for devices with compact layouts such as control cabinets and small sensor modules. The panel opening size complies with the M8 interface standard, ensuring high assembly efficiency.
Material Selection:The contact bodies are made of copper alloy with nickel and gold plating on the surface, which not only ensures excellent electrical conductivity but also enhances wear and corrosion resistance. Wide Applications:It is widely used in equipment including industrial automation production lines, small industrial robots, micro servo motors and intelligent sensors.
|
Product model
|
Core
|
Rated current
|
Rated voltage
|
Wire gauge / Dimension
|
|||
|
A/C
|
D/C
|
AWG
|
mm²
|
||||
|
MC08DM-04R2LSLNS1401
|
4
|
3A
|
60V
|
60V
|
24
|
0.25
|
|
| Core | 3A | 4A | 6A |
| Male |
|
|
|
| 8A | 5B | 4D | |
|
|
|
|
|
| Core | 3A | 4A | 6A |
| Female |
|
|
|
| 8A | 5B | 4D | |
|
|
|
|
The connector must not be plugged or unplugged under load. Failure to follow the instructions and improper use can result in personal injury.
The development of the connector is aimed at being applied in factory engineering, control and electrical equipment construction. Users are responsible for checking whether the connector can also be used in other applications.
Connectors used in circuits with dangerous voltages that cause electric shock must be installed and used only by personnel who have received training in electrical engineering, or under their supervision, while taking into account the applicable regulations and standards.
Users must take appropriate security measures to ensure that the connectors do not accidentally disconnect.
When installing, apply moderate force and use the special tool to tighten the nuts. Avoid excessive force to prevent the shell from deforming or the pins from bending. Ensure that the plug and socket are fully engaged. Do not power on the device when not locked in place to prevent arc discharge due to poor contact.
The plug connectors with an enclosure protection rating of IP67 and IP68 are not suitable for use in water. When used outdoors, the plug connectors must be protected against corrosion separately. For further information on IP protection ratings, please refer to "Technical Information".